Sample report. This is a fully worked example using representative data for an 8.4 kW system in Austin, TX — not a real customer's system. Every section below is the live product, rendered by the same code as a real report.

Solar Health Report

Barton Hills House

8.4 kW · Enphase · July 2026

±5-7%
78
Watch

Your system needs attention

Produced
1,023
kWh
Expected
1,320
kWh
Output Rate
78%
vs expected

Score trend

Trending down 2 points/month

Dashed line marks a healthy score of 85.

Weather wasn’t the issue

July weather was close to typical. Your system produced 297 kWh less than physics predicts for those conditions, so the shortfall is from something else.

Hot panels cost about 166 kWh in July

Panels ran roughly 36°C hotter than their lab rating (25°C cell temperature). Hot panels produce less power — that's a ~12.6% loss, about 166 kWh worth $25. It's normal and baked into your expected output.

CriticalDegradation check · 13 months of data

Unusual loss rate — worth investigating now

Your panels are producing about 2.1% per year less than expected for their age and weather. That's roughly 5.2× your warranty's allowed degradation. If this is degradation, projected impact is $4,236 in lost production over 25 years. Shading, soiling, or a hardware fault can look the same on paper.

Observed excess
2.1%/yr
Warranty allows
0.5%/yr
25-yr impact
$4,236

What to do: Contact your installer. If they can't explain it, the manufacturer may cover a replacement under warranty.

Year-to-Date Savings
vs. grid electricity at $0.15/kWh
$1,012

Monthly Production

🏘️
Your Neighborhood

Your system has performed better than 38% of systems in your area over the past 3 months.

78704 · 3-Month Average Output Rate
1
97%
2
96%
3
95%
21
You
78%
22
77%
Anonymous · Based on 34 systems in your area
🔮
Looking Ahead

Next month, typical sunlight for your location is 118% of your yearly average, based on seasonal patterns. August is historically your system's 2nd strongest month, so expect production to decrease as days get shorter.

August Forecast: ~1,290 kWh expected
Based on typical sunlight for your location

What this means

Last month's production was well below what your system produced in the same month last year — more than expected aging can explain.

  • New or increased shading from trees or nearby structures
  • A panel, microinverter, or component that has partially or fully failed
  • Inverter operating at reduced efficiency

What to do: Schedule an inspection with your solar installer. Bring your monitoring data — the trend over the past few months will help them diagnose the issue quickly.

Want this for your own system?

Join the waitlist and we'll send you a health report built from your own production data.